WS510-UMB Smart Weather Sensor
First and only Smart Weather Sensor with integrated Kipp & Zonen CMP10 Pyranometer (secondary standard)
From the WS product family of professional intelligent measurement transducers with digital interface for environmental applications. Integrated design with ventilated radiation protection for measuring: Air temperature, relative humidity, air pressure, wind direction, wind speed and radiation. One external temperature or rain sensor is connectable.
- Temperature, relative humidity, air pressure, wind direction, wind speed, radiation
- Ultrasonic/Wind, NTC/T, Capacitive/RH, MEMS capacitive/Pressure, Kipp&Zonen/Radiation
- Wind detection with birdproof construction. Compact all-in-one weather sensor, low power, heater, aspirated radiation shield, maintenance-free operation, open communication protocol.
- RS485 with supported protocols UMB-Binary, UMB-ASCII, Modbus-RTU, Modbus-ASCII, XDR and SDI-12
- 8375.5
Advantages of the Smart Weather Sensor WS510
- Measuring wind direction and speed insusceptibly to bird nesting thanks to roofed construction
- All-in-one housing concept of a compact weather sensor combining 6 measurement parameters in one housing with only one cable connection
- First and only compact weather sensor with integrated Kipp & Zonen CMP10 Pyranometer with secondary standard quality
- Built-in data pre-processing, universal interfaces and selectable output protocols
- Compatible with many commercially available Met/HydroMet dataloggers and PLS systems thanks to an open communication protocol
- Maintenance-free operation – no moving parts that can wear out
- Suitable for all climate zones; also for solar-powered automatic meteorological stations
- Ventilated temperature and humidity measurement according to WMO guidelines
- Integrated heater that can be switched on if there is danger of frost
Examples of use of the Smart Weather Sensor WS510
The robust and maintenance-free smart weather sensor WS510 is designed for professional meteorological applications in all climate zones. It delivers reliable data, even in extreme ambient conditions.
Examples of use:
- PV-Monitoring / Solar Monitoring on photovoltaic farms
- Automatic weather station (AWS)
- Hydro-meteorological stations
- Meteorological reference stations
- Integration into various other systems/solutions, where this measurement parameters are needed...
EU declaration of conformity - Lufft WS Family
EU declaration of conformity - Lufft WS Family
|
Firmware - WSXXX
For WSXXX device versions 1 - 29 (see serial number) / Für WSXXX Geräteversionen 1 - 29 (siehe Seriennummer)
|
Firmware - WSXXX v70
For WSXXX device versions ≥30 (see serial number)
|
|
|
|
|
|
|
General | |
Dimensions | Ø approx. 150 mm, height approx. 332 mm |
Weight | Approx. 1.5 kg |
Interface | RS485, 2 - wire, half - duplex |
Power supply | 11…32 VDC |
Power supply | 5 … 11 VDC (electronics with limited precision of measurements) |
Power supply | 24 VDC +/- 10% (heater) |
Power consumption | 20 VA (heater) |
Operating temperature | -50...60 °C (with heater) |
Operating rel. humidity | 0...100 % RH |
Cable length | 10 m |
Protection level housing | IP66 |
Mast mounting suitable for | Mast diameter 60 - 76 mm |
Temperature | |
Principle | NTC |
Measuring range | -50 ... 60 °C |
Unit | °C |
Accuracy | ±0.2 °C (-20...50 °C), otherwise ±0.5 °C (>-30 °C) |
Relative humidity | |
Principle | Capacitive |
Measuring range | 0 ... 100 % RH |
Unit | % RH |
Accuracy | ±2 % RH |
Air pressure | |
Principle | MEMS capacitive |
Measuring range | 300 ... 1200 hPa |
Unit | hPa |
Accuracy | ±0.5 hPa (0...40 °C) |
Wind direction | |
Principle | Ultrasonic |
Measuring range | 0 ... 359.9 ° |
Unit | ° |
Accuracy | < 3° RMSE > 1.0 m/s |
Resolution | 0.1 |
Wind speed | |
Principle | Ultrasonic |
Measuring range | 0 ... 75 m/s |
Unit | m/s |
Accuracy | ±0.3 m/s or ±3 % (0...35 m/s) ±5 % (>35 m/s) RMS |
Resolution | 0.1 m/s |
Radiation | |
Response time | < 5 s |
Zero offset A | < 7 W/m² |
Zero offset B | < 2 W/m² |
Directional error (at 1000 W/m²) | < 0.2 % |
Temperature dependence of sensitivity | < 1 % (-10 ºC...40 ºC) |
Spectral range | 285 to 2,800 nm |
Measuring range | 4000 W/m² |
WS product family: Communication after protocol change
How to communicate with a WS-Sensor and the UMB-config-Tool if the protocol was changed for example to Modbus or SDI-12?
After a Reset ( switching On/Off the sensor) every WS-Senor will start up for the first 5 seconds in UMB-protocol and the standard baud rate of 19200Bd. Independend to the configured protocol and baudrate settings of the WS-Sensor.
In this first 5 Seconds you will be able to connect via UMB-config-Tool to the WS-Sensor after this first command was send the UMB-protocol will stay for 10 minutes after that it switches back to the original configured protocol. This Time will always be extended to 10 minutes if a new UMB command was send.
WS product family: SDI-12 wiring plan for Device version >= 42
How to connect a WS-sensor with a device version >= 42 (hardware version >=14) to a SDI-12 system?
The wiring plan has changed compared to the wiring plan of older WS-Sensor device versions.
The new wiring plan is:
- +VDD = brown
- GND = white
- SDI12_Signal = yellow
- SDI12_GND = white
This is also mentioned as a note in the latest WS-sensor manual in the section 8 Connections