Outdoor PT100 Temperature Sensor
External PT100, 4 wire temperature sensor, with two different cable lengths. Sensor is usually connected to the ANACON and used in road weather applications.
- 8160.TF25S, 8160.TF50S
Product variants - Temperature probe
We offer three different cable lenghts you can get the sensor with:
- Temperature sensor, external, 25m cable
- Temperature sensor, external, 50m cable
|
Connection diagram: Temperature sensor 8160.TF25S to ANACON
Connection diagram: Temperature sensor 8160.TF25S to ANACON
|
Download as PDF
Download as PDF
| General | |
| Dimensions | Length 50 mm, Ø 8 mm |
| Output signal | Resistance |
| Cable length | 25/50 m |
| Protection type | IP67 |
| Connector | Open wires |
| Operating temperature | -40...80 °C |
| Operating rel. humidity | 0...100 % RH |
| Accuracy | Class A |
| Temperature | |
| Principle | PT100 |
| Accuracy | ±0.3 K@0 °C |