Lufft OPUS20 - An essential data collector for all calibration laboratories measuring precise temperature, relative humidity and air pressure!
The only LAN datalogger with built-in sensors and the highest precision! Firmware online updatable. The OPUS20 runs on batteries or powered via USB. Alternatively, you have the possibility to power the device via POE (Power over Ethernet).
IMPORTANT: OPUS 20 THIP is discontinued
- Temperature, relative humidity and air pressure
- Temperature & air pressure / NTC, Humidity / Capacitive
- LAN datalogger with built-in sensors and highest precision, evaluation software SmartGraph3 included
- USB (Cable and SmartGraph3 monitoring software included)
- 8120.10, 8120.10N, 8120.11, 8120.11N
Advantages of the indoor/inroom datalogger OPUS 20 THIP
- LAN capabilities to realize universal measurement networks in real time
- Innovative housing design with different wall mounting options
- Monitoring and evaluation software SmartGraph3 included
- Power over Ethernet (PoE) available as option
- Power supply via batteries as well as USB-Connection possible
- Firmware online updatable
- If 21 CFR 11 guidelines have to be fulfilled, the well-established and proven MCPS8 software is available
Examples of the indoor/inroom datalogger OPUS 20 THIP
The LAN datalogger OPUS 20 THIP with built-in sensors and the highest precision is often used in the following applications:
- Climate monitoring in buildings
- control of all climate-sensitive production processes
- in electronic data-processing centres
- control cabinets
- wind turbines
- storage rooms
- museums
- many other climate-sensitive applications…
Product variants - Opus 20 THIP
The OPUS 20 THIP indoor datalogger is available in 4 product variants:
- Opus 20 THIP (Article no. 8120.10)
- Opus 20 THIP, Neutral = without Lufft branding (Article no. 8120.10N)
- OPUS 20 THIP, PoE = Power over Ethernet energy supply (Article no. 8120.11)
- OPUS 20 THIP, PoE, Neutral = Power over Ethernet energy supply, without Lufft branding (Article no. 8120.11N)
|
General | |
Dimensions | 166 x 78 x 32 mm |
Measuring interval | 10/30 s, 1/10/12/15/30 min, 1/3/6/12/24 h |
Construction | Plastic housing |
Operating time with battery | > 1 Year |
Data storage | 16 MB, 3,200,000 measured values |
LC-Display | Height 90 x 64 mm |
Weight | Approx. 250 g |
Included in delivery | PC - Windows Software SmartGraph 3 For graphical and numerical representation of measured values / instruction manual / data cable / battery / DIN rail bracket |
Interface | USB, LAN |
Storage interval | 1/10/12/15/30 min, 1/3/6/12/24 h |
Power supply | 4 x LR6 AA Mignon, USB |
Operating temperature | -20...50 °C |
Operating rel. humidity | 0...100 % RH, < 20 g/m³ (non - condensing) |
Max. height | 10,000 m above sea level |
Temperature | |
Principle | NTC |
Measuring range | -20 ... 50 °C |
Unit | °C |
Accuracy | ±0.3 °C (0...40 °C), otherwise ± 0.5 °C |
Resolution | 0.1 |
Relative humidity | |
Principle | Capacitive |
Measuring range | 0 ... 100 % RH |
Unit | % RH |
Accuracy | ±2 % RH |
Resolution | 0.1 |
Air pressure | |
Measuring range | 300 ... 1300 hPa abs. |
Unit | hPa abs. |
Accuracy | 700...1100 hPa at 25 °C ±0.5 hPa |
Resolution | 0.1 |
OPUS20: How can the data be recorded in the internal memory of the OPUS20?
The OPUS20 must be configured in Mode M3 REC or M4 REC Hide. This can be done using the configuration button on the back of the OPUS20.
OPUS20: What are the eletrical specifications for the PoE version of the OPUS20 device?
The OPUS20 PoE version uses a voltage level of 48V and the lowest current level
OPUS20: Is ethernet communication available for all OPUS20 versions?
Yes, the etherent interface is a part of all OPUS20 instruments, so all of them cam be connected to the network (LAN)
OPUS20 and SmartGraph3: Is SmartGraph3 (min. V3.2.0) compatible to Windows7/10?
Yes, SmartGraph3 was tested under Windows 7 & Windows 10 and no problems were found.
OPUS20 and SmartGraph3: How to work with SmartGraph3 Monitoring Software?
In the tutorial video we answer many questions from first steps with OPUS20 and SmartGraph3 to different configuration options:
Startup OPUS20
- Installation SmartGraph 3 (03:18 min)
SmartGraph 3
- Software settings (05:05 min)
- Manage devices (07:21 min)
- Diagram view settings (10:22 min)
- data export (14:25 min)
- print function (15:15 min)
- Software- and firmware-update (16:58 min)
To the Tutorial Video: