toggle menu

Power supply 24V/4A

Power supply 24V/4A 
  • 8366.USV1
Request a quote or advice
Download as PDF
OUTPUT
DC VOLTAGE 24V
RATED CURRENT 4.2A
CURRENT RANGE 0 ~ 4.2A
RATED POWER 100.8W
RIPPLE & NOISE (max.) 150mVp-p
VOLTAGE ADJ. RANGE 24 ~ 29V
VOLTAGE TOLERANCE ±1.0%
LINE REGULATION ±1.0%
LOAD REGULATION ±1.0%
SETUP, RISE TIME 2700ms, 80ms/230VAC 2700ms, 80ms/115VAC at full load
HOLD UP TIME (Typ.) 50ms/230VAC 18ms/115VAC at full load
INPUT
VOLTAGE RANGE 88 ~ 264VAC 124 ~ 370VDC [DC input operation possible by connecting AC/L(+),AC/N(-)]
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 89%
AC CURRENT (Typ.) 3A/115VAC 1.6A/230VAC
INRUSH CURRENT (Typ.) COLD START 30A/115VAC 45A/230VAC
PROTECTION
OVERLOAD 105 ~ 135% rated output power;
Protection type: Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 30 ~ 35V;
Protection type: Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, re-power on to recover
ENVIRONMENT
WORKING TEMP. -20 ~ +60°C (refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/°C (0 ~ 50 °C)
VIBRATION Component: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY & EMC
SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved, design refer to EN50178
WITHSTAND VOLTAGE I/P-O/P:3KVAC
ISOLATION RESISTANCE I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to EN61204-3, EN55032 Class B, EN61000-3-2,-3
EMC IMMUNITY Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
OTHERS
MTBF 486K hrs min. MIL-HDBK-217F (25℃)
DIMENSION 100*93*56mm (W*H*D)
PACKING 0.35Kg; 36pcs/13.6Kg/0.89CUFT
Download as PDF
Back