toggle menu

WS502-UMB Smart Weather Sensor

Compact all-in-one weather sensor with measurement of temperature, relative humidity, air pressure, wind direction, wind speed and radiation.

From the WS product family of professional intelligent measurement transducers with digital interface for environmental applications. Integrated design with ventilated radiation protection for measuring: Air temperature, relative humidity, air pressure, wind direction, wind speed and radiation. One external temperature or rain sensor is connectable.

  • Temperature, relative humidity, air pressure, wind direction, wind speed, radiation
  • Ultrasonic/Wind, NTC/T, Capacitive/RH, MEMS capacitive/Pressure, Lufft Pyranometer/Radiation
  • Wind detection with birdproof construction. Compact all-in-one weather sensor, low power, heater, aspirated radiation shield, maintenance-free operation, open communication protocol.
  • RS485 with supported protocols UMB-Binary, UMB-ASCII, Modbus-RTU, Modbus-ASCII, XDR and SDI-12
  • 8375.U10
Request a quote or advice

Advantages of the Smart Weather Sensor WS502

  • Measuring wind direction and speed insusceptibly to bird nesting thanks to roofed construction
  • All-in-one housing concept of a compact weather sensor combining 6 measurement parameters in one housing with only one cable connection
  • Built-in data pre-processing, universal interfaces and selectable output protocols
  • Compatible with many commercially available Met/HydroMet dataloggers and PLS systems thanks to an open communication protocol
  • Maintenance-free operation – no moving parts that can wear out
  • Suitable for all climate zones; also for solar-powered automatic meteorological stations
  • Ventilated temperature and humidity measurement according to WMO guidelines
  • Integrated heater that can be switched on if there is danger of frost

Examples of use of the Smart Weather Sensor WS502

The robust and maintenance-free smart weather sensor WS502 is designed for professional meteorological applications in all climate zones. It delivers reliable data, even in extreme ambient conditions.

Examples of use:

  • Weather observation for road and traffic control systems
  • Automatic weather station / Automatic weather sensor (AWS)
  • PV-Monitoring / Solar Monitoring on photovoltaic farms
  • Hydro-meteorological stations
  • Weather observation for building automation
  • Weather stations at airports, marinas and onboard ships
  • Integration into various other systems/solutions, where environmental data is needed...
EU declaration of conformity - Lufft WS Family
EU declaration of conformity - Lufft WS Family
Firmware - WSXXX
For WSXXX device versions 1 - 29 (see serial number) / Für WSXXX Geräteversionen 1 - 29 (siehe Seriennummer)
Firmware - WSXXX v70
For WSXXX device versions ≥30 (see serial number)
Full User Manual - Lufft WSxxx weather sensors
Manual - Lufft UMB Config Tool (EN)
Manual - Lufft UMB Protocol (EN)
Operational Manual - Lufft WSxxx weather sensors
Quickstart - Lufft WSXXX - Smart Weather Sensor Family (DE/EN)
Software - Lufft - ConfigTool .NET
Version 1.6
Software - UMB Config Tool
Download as PDF
General
Dimensions Ø approx. 150 mm, height approx. 317 mm
Weight Approx. 1.5 kg
Interface RS485, 2 - wire, half - duplex
Power supply 11…32 VDC
Power supply 5…11 VDC (electronics with limited precision of measurements)
Power supply 24 VDC +/- 10% (heater)
Power consumption 20 VA (heater)
Operating temperature -50...60 °C (with heater)
Operating rel. humidity 0...100 % RH
Protection level housing IP66
Standards/Regulations Compliant to IEC 61724-1:2017 Class C
Mast mounting suitable for Mast diameter 60 - 76 mm
Radiation
Unit W/m²
Accuracy 5 %
Response time (95%) < 1 s
Non-stability(change/year) ±1 %
Non-linearity (0 to 1000 W/m²) ±1 %
Directional error (at 80° with 1000 W/m²) ±20 W/m²
Temperature dependence of sensitivity ±5 % (-10 to +40 °C)
Tilt error (at 1000 W/m²) ±1 %
Spectral range 300...1100 nm
Measuring range 1400 W/m²
Temperature
Principle NTC
Measuring range -50 ... 60 °C
Unit °C
Accuracy ±0.2 °C (-20...50 °C), otherwise ±0.5 °C (>-30 °C)
Relative humidity
Principle Capacitive
Measuring range 0 ... 100 % RH
Unit % RH
Accuracy ±2 % RH
Air pressure
Principle MEMS capacitive
Measuring range 300 ... 1200 hPa
Unit hPa
Accuracy ±0.5 hPa (0...40 °C)
Wind direction
Principle Ultrasonic
Measuring range 0 ... 359.9 °
Unit °
Accuracy < 3 ° RMSE > 1.0 m/s
Resolution 0.1
Wind speed
Principle Ultrasonic
Measuring range 0 ... 75 m/s
Unit m/s
Accuracy ±0.3 m/s or ±3 % (0...35 m/s) ±5 % (>35 m/s) RMS
Resolution 0.1 m/s
Download as PDF

WS product family: Communication after protocol change

How to communicate with a WS-Sensor and the UMB-config-Tool if the protocol was changed for example to Modbus or SDI-12?

After a Reset ( switching On/Off the sensor) every WS-Senor will start up for the first 5 seconds in UMB-protocol and the standard baud rate of 19200Bd. Independend to the configured protocol and baudrate settings of the WS-Sensor.

In this first 5 Seconds you will be able to connect via UMB-config-Tool to the WS-Sensor after this first command was send the UMB-protocol will stay for 10 minutes after that it switches back to the original configured protocol. This Time will always be extended to 10 minutes if a new UMB command was send.

WS product family: SDI-12 wiring plan for Device version >= 42

How to connect a WS-sensor with a device version >= 42 (hardware version >=14) to a SDI-12 system?

The wiring plan has changed compared to the wiring plan of older WS-Sensor device versions.
The new wiring plan is:

  • +VDD = brown
  • GND = white
  • SDI12_Signal = yellow
  • SDI12_GND = white

This is also mentioned as a note in the latest WS-sensor manual in the section 8 Connections

Back